1:4.2 Increasing 45° Fiber-Optic Handpiece – Premium Range

Precision-engineered for speed, torque, and accessibility, this premium 45° contra-angle is the go-to handpiece for extractions, surgical sectioning, and difficult crown preparations.

Designed to combine superior engineering with ergonomic handling, it delivers exceptional performance when driven by an electric micromotor for maximum torque.

Key Features

  • Premium Gear Engineering – Advanced gear system for smoother running, reduced vibration, and extended service life.

  • Optimized 45° Head Angle – Perfect for surgical access, especially when sectioning teeth for extractions or reaching challenging preparation margins.

  • High-Speed, High-Torque Performance – Achieves up to 168,000 rpm with a micromotor for fast, efficient cutting.

  • Fiber-Optic Illumination – Clear, focused lighting at the bur tip for enhanced visibility in all working conditions.

  • Push-Button Chuck System – Quick, secure bur changes to keep workflow efficient.

  • Compatible with Ø1.6 mm burs – Accepts standard FG burs for versatility across procedures.

Why Choose a 45° Speed-Increasing Handpiece?

The angled head gives superior access in surgical procedures and allows better approach angles during complex restorative work. When paired with a micromotor, the improved torque and consistent speed make it an invaluable addition to any dental toolkit.

Premium Range – Built for Reliability

As part of our Premium Range, this handpiece is engineered for reduced maintenance needs and longer service intervals, offering one of the lowest lifetime cost-per-use profiles on the market.

This is premium performance—without the premium markup.

Materials

Shipping & Returns

Dimensions

Care Instructions

Maintenance and Safe Use of Speed Increasing Handpieces
Introduction
Speed increasing handpieces are essential tools in dental practices, designed to enhance precision and efficiency during procedures. Proper maintenance and safe use are crucial for ensuring the longevity of the handpieces and the safety of both the operator and the patient.
Maintenance Instructions
1. Cleaning, Lubrication, and Purging after each use:
o Cleaning: Use a brush and deionised water to clean the external surfaces of the handpiece only. Avoid soaking the handpieces in water or chemicals as this can lead to corrosion.
o Lubrication: Apply lubricant to the drive air tube and the moving parts as recommended by the manufacturer. Oiling the handpiece prior to autoclaving is essential to promote the smooth running of gears and bearings. Failing to do so can significantly impair performance and reduce lifespan as well as cause overheating.
o Purging: The handpiece must be purged of excess oil before autoclaving. Failure to purge excess oil can cause the formation of a slurry during the autoclaving process. This slurry can lead to overheating and premature failure of gears and bearings during use.
2. Sterilization:
o Autoclaving: After cleaning, lubrication, and purging, place the handpiece in an autoclave pouch and sterilize it in an autoclave. Follow the manufacturer's guidelines for temperature and cycle duration.
o Avoid Chemical Sterilants: Do not use chemical sterilants unless specifically recommended by the manufacturer, as these can damage the internal components.
3. Periodic Maintenance:
o Inspection: Regularly inspect the handpiece for signs of wear and tear, such as cracks or loose parts.
We would typically expect our speed increasing bearings to last between 6-12 months dependent on maintenance protocol and usage. Proper maintenance can significantly improve that duration however it is important be aware that speed increasing handpiece have significantly higher maintenance demands and costs than high speed turbines.
Safe Use Instructions
1. Pre-Use Checks:
o Clinician’s Responsibility: It is the clinician's responsibility to ensure the safe function of each handpiece prior to use on a patient.
o Visual Inspection: Before each use, visually inspect the handpiece for any damage or abnormalities.
o Function Test: Run the handpiece through for 30 seconds to ensure there are no signs of bearing failure such as excessive vibration, noise, or heat. Check that burs rotate properly and about their central axis.
o Initial Heat Dissipation: Be aware that there can be excess heat when the handpiece is first used post-autoclaving as the gears engage and any debris is cleared. Ensuring this excess heat has dissipated prior to use on a patient is essential.
2. Proper Handling:
o Grip and Control: Hold the handpiece with a firm grip to maintain control during use. Avoid applying excessive force, which can damage both the handpiece.
o Avoid Dropping: Handle the handpiece carefully to avoid dropping it, as impacts can misalign the internal components.
3. Operational Precautions:
o Use the Correct Burs: Ensure the burs used are compatible with the handpiece and are properly inserted and secured.
o Speed Settings: Operate the handpiece at the recommended speed settings for different procedures to prevent excessive wear and potential injury.
o Avoid Soft Tissue Contact: Always ensure that the head of the handpiece is not in contact with the patient’s soft tissues, as the handpiece can generate heat and cause burns.
o Bearing Failure Vigilance: Be aware that often, when a speed increasing handpiece bearings fail, the bur will continue to cut, however, excess heat will be generated. Be vigilant for other signs of bearing failure to avoid overheating, which can cause damage to both the operator and the patient.
4. Post-Use Protocol:
o Immediate Cleaning: After use, immediately clean the handpiece to remove debris and prevent build-up.
o Storage: Store the handpiece in a clean, dry place. Use protective caps or cases to prevent contamination and damage.
Additional Tips
• User Training: Ensure all operators are properly trained in the use and maintenance of speed increasing handpieces.
• Manufacturer’s Manual: Always refer to the manufacturer's manual for specific instructions and recommendations for your particular model.
• Record Keeping: Maintain a log of maintenance and sterilization procedures to track the handpiece's condition and service history.

View full details
delivery--v1

UK Delivery Within 5 Working Days

Your orders are shipped with Fedex and usually arrive much quicker. We prefer to under promise and overdeliver however! Orders over £100 ship for free.

external-delivery-box-shopping-online-kmg-design-detailed-outline-kmg-design

Unrivalled Value

We are market disrupters: no reps, no trade shows, no course sponsorship, no freebies. All this means consistently better prices for our customers.

gift--v1

Online Customer Service

We offer super responsive online support that we are really proud of. Emailing us is the most efficient way for us to help you

external-headphone-devices-icongeek26-glyph-icongeek26-1

Curated Range

No need to spend valuable time scrolling through page after page of iterations of the same product. We've done the work hard for you; we would'nt use it, we wont sell it!

external-headphone-devices-icongeek26-glyph-icongeek26-1

EU Delivery 2 - 11 Days

Orders from the EU will be delivered, duty paid, via FEDEX. No taxes or duties to pay once your order arrives!

Notify Me When Available

Fill in the required details to get notified when the product is back in stock.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)