Pomiń, aby przejść do informacji o produkcie
1 z 3

Handpiece Club

×
1:5 Handpieces (with External water supply)

We often restock popular items or they may be returned by the other customers. If you would like to be notified when this happens just enter your details below.


1:5 Handpieces (with External water supply)

Proszę wybrać wariant
Proszę podać nazwę
Nieprawidłowy adres e-mail
Wymagany numer telefonu komórkowego Nieprawidłowy numer Nieprawidłowy kod kraju Zbyt krótki Za długo ✓Prawidłowy
Tylko zwykły tekst nie jest dozwolony w wiadomości Długość wiadomości musi wynosić 250 znaków
Kraj jest wymagany

Jeśli WhatsApp nie będzie mógł dostarczyć powiadomienia, możemy wysłać je SMS-em na ten sam numer.

Twoje powiadomienie zostało zarejestrowane. Zamknij

Szanujemy Twoją prywatność i nie udostępniamy nikomu Twojego adresu e-mail.

×

1:5 Handpieces (with External water supply)

1:5 Handpieces (with External water supply)

Cena regularna £504.00 GBP
Cena regularna Cena sprzedaży £504.00 GBP
Sprzedaż Wyprzedane
Z wliczonym podatkiem.
Style

Speed increasing motors can work with air motors, or ideally, micromotors to allow varied speed and increased torque for tooth preparation.

For surgical applications it is optimal to have the water come from an external water supply so sterile water can be delivered and no air is used to pressurise and deliver the water through the handpiece.

These handpieces can only be used with irrigation when a external irrigation supply is connected to them (eg. E-type implant motors). Sterile disposable tubing (sold separately) is required to connect the handpieces to the external water supply.

Handpiece club

When you buy one of our handpiece club products you are not just buying the handpiece but also our service guarantee.

As you all know handpieces require maintenance and no matter the brand (or oiling regimen) they will often seize after 6-9 months. Sometimes they last longer, sometimes shorter but it will always occur.

This is because the bearings inside the handpieces are classed as a consumable item. They are actually rarely covered under manufacturers warranties. Also when you send your hand-piece for repair they are often repaired with a generic low quality bearing that is not designed for your hand-piece.

We think it’s time to stop cursing the repair of handpieces and instead prepare for it. We can change a bearing quickly (with a high quality compatible bearing) and get it straight back to you or we will simply replace the handpiece if the repair is more involved.

We know that chair time is so expensive in dentistry and we are fully committed to keeping your equipment working!

As with all Incidental handpieces, you’ll receive our 1-year repair or replace warranty. All repairs are carried out in-house at our purpose-built repair centre, where our renowned service ensures super-fast turnaround times to keep your practice running smoothly.

Care Instructions

Maintenance and Safe Use of Speed Increasing Handpieces
Introduction
Speed increasing handpieces are essential tools in dental practices, designed to enhance precision and efficiency during procedures. Proper maintenance and safe use are crucial for ensuring the longevity of the handpieces and the safety of both the operator and the patient.
Maintenance Instructions
1. Cleaning, Lubrication, and Purging after each use:
o Cleaning: Use a brush and deionised water to clean the external surfaces of the handpiece only. Avoid soaking the handpieces in water or chemicals as this can lead to corrosion.
o Lubrication: Apply lubricant to the drive air tube and the moving parts as recommended by the manufacturer. Oiling the handpiece prior to autoclaving is essential to promote the smooth running of gears and bearings. Failing to do so can significantly impair performance and reduce lifespan as well as cause overheating.
o Purging: The handpiece must be purged of excess oil before autoclaving. Failure to purge excess oil can cause the formation of a slurry during the autoclaving process. This slurry can lead to overheating and premature failure of gears and bearings during use.
2. Sterilization:
o Autoclaving: After cleaning, lubrication, and purging, place the handpiece in an autoclave pouch and sterilize it in an autoclave. Follow the manufacturer's guidelines for temperature and cycle duration.
o Avoid Chemical Sterilants: Do not use chemical sterilants unless specifically recommended by the manufacturer, as these can damage the internal components.
3. Periodic Maintenance:
o Inspection: Regularly inspect the handpiece for signs of wear and tear, such as cracks or loose parts.
We would typically expect our speed increasing bearings to last between 6-12 months dependent on maintenance protocol and usage. Proper maintenance can significantly improve that duration however it is important be aware that speed increasing handpiece have significantly higher maintenance demands and costs than high speed turbines.
Safe Use Instructions
1. Pre-Use Checks:
o Clinician’s Responsibility: It is the clinician's responsibility to ensure the safe function of each handpiece prior to use on a patient.
o Visual Inspection: Before each use, visually inspect the handpiece for any damage or abnormalities.
o Function Test: Run the handpiece through for 30 seconds to ensure there are no signs of bearing failure such as excessive vibration, noise, or heat. Check that burs rotate properly and about their central axis.
o Initial Heat Dissipation: Be aware that there can be excess heat when the handpiece is first used post-autoclaving as the gears engage and any debris is cleared. Ensuring this excess heat has dissipated prior to use on a patient is essential.
2. Proper Handling:
o Grip and Control: Hold the handpiece with a firm grip to maintain control during use. Avoid applying excessive force, which can damage both the handpiece.
o Avoid Dropping: Handle the handpiece carefully to avoid dropping it, as impacts can misalign the internal components.
3. Operational Precautions:
o Use the Correct Burs: Ensure the burs used are compatible with the handpiece and are properly inserted and secured.
o Speed Settings: Operate the handpiece at the recommended speed settings for different procedures to prevent excessive wear and potential injury.
o Avoid Soft Tissue Contact: Always ensure that the head of the handpiece is not in contact with the patient’s soft tissues, as the handpiece can generate heat and cause burns.
o Bearing Failure Vigilance: Be aware that often, when a speed increasing handpiece bearings fail, the bur will continue to cut, however, excess heat will be generated. Be vigilant for other signs of bearing failure to avoid overheating, which can cause damage to both the operator and the patient.
4. Post-Use Protocol:
o Immediate Cleaning: After use, immediately clean the handpiece to remove debris and prevent build-up.
o Storage: Store the handpiece in a clean, dry place. Use protective caps or cases to prevent contamination and damage.
Additional Tips
• User Training: Ensure all operators are properly trained in the use and maintenance of speed increasing handpieces.
• Manufacturer’s Manual: Always refer to the manufacturer's manual for specific instructions and recommendations for your particular model.
• Record Keeping: Maintain a log of maintenance and sterilization procedures to track the handpiece's condition and service history.

Pokaż kompletne dane
delivery--v1

Dostawa do Polski w 2–11 dni

Dostępne zamówienia wysyłamy przez FedEx. Opcje dostawy i całkowity koszt są widoczne podczas realizacji zamówienia.

external-delivery-box-shopping-online-kmg-design-detailed-outline-kmg-design

Dobra relacja jakości do ceny

Utrzymujemy prosty model kosztowy, aby oferować konkurencyjne ceny naszym klientom.

gift--v1

Obsługa klienta online

Nasz zespół oferuje szybką pomoc online. E-mail jest zwykle najsprawniejszym sposobem rozwiązania pytań o produkty i zamówienia.

external-headphone-devices-icongeek26-glyph-icongeek26-1

Starannie dobrany asortyment

Skupiamy się na wybranych produktach, które sami uznajemy za przydatne klinicznie.

external-headphone-devices-icongeek26-glyph-icongeek26-1

Dostawa do UE z opłaconymi należnościami

W przypadku opcji wysyłki do UE dostępnych w kasie przy doręczeniu nie są pobierane dodatkowe podatki ani cła.

×
1:5 Handpieces (with External water supply)

We often restock popular items or they may be returned by the other customers. If you would like to be notified when this happens just enter your details below.


Proszę wybrać wariant
Proszę podać nazwę
Nieprawidłowy adres e-mail
Wymagany numer telefonu komórkowego Nieprawidłowy numer Nieprawidłowy kod kraju Zbyt krótki Za długo ✓Prawidłowy
Tylko zwykły tekst nie jest dozwolony w wiadomości Długość wiadomości musi wynosić 250 znaków
Kraj jest wymagany

Jeśli WhatsApp nie będzie mógł dostarczyć powiadomienia, możemy wysłać je SMS-em na ten sam numer.

Twoje powiadomienie zostało zarejestrowane. Zamknij

Szanujemy Twoją prywatność i nie udostępniamy nikomu Twojego adresu e-mail.

×

Thank you, we have now received and recorded your request to be notified should 1:5 Handpieces (with External water supply) be restocked.

We will only use your email for this purpose.